Michael S <[log in to unmask]> on 6/22/99 wrote:

> All,

> We need help in resolving a telnet connection problem with our  HP 3000
> 918lx system, we have contacted HP and the costs for HP service are
> prhibitive for our needs. This means we need to find a service
> organization (other than HP) who can provide an onsite service call for
> the above mentioned system installed in Houston, Texas (I-10 Energy >
Corridor).

<snip>

> The system has been restarted several times, and even restored using a
> backup tape. The trigger to this event seems to have been a building wide
> power failure prior to the problem occuring. If anyone has any
> suggestions or can be of assistance please feel free to email me.

Michael,

The resolution to your problem may be as simple as STREAMing the job
JINETD.NET.SYS.  This job logs on as JINETD,MANAGER.SYS.  This job controls
whether or not Telnet works.  It MUST be left running all the time that you
want telnet to work.

HTH,

John Hornberger
Sr. Systems Programmer
General Signal Services (A subsidiary of SPX Corp.)