HP3000-L Archives

September 1995, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Sender:
HP-3000 Systems Discussion <[log in to unmask]>
Subject:
From:
Jeff Kell <[log in to unmask]>
Date:
Tue, 12 Sep 1995 15:26:05 EDT
Comments:
Resent-From: Jeff Kell <[log in to unmask]> Originally-From: "L-Soft list server at UTCVM (1.8b)" <[log in to unmask]>
Reply-To:
Parts/Attachments:
text/plain (25 lines)
Forwarded for Mike Baker...
----------------------------Original message----------------------------
The enclosed mail file has been identified as a delivery error for list
HP3000-L because it was sent to the reserved 'owner-hp3000-l' mailbox.
------------------------------ Message in error -------------------------------
From: "Baker, Mike" <[log in to unmask]>
Subject: RE: Terminal Communications
Date: Wed, 13 Sep 95 14:05:00 PDT
 
We have used a serial line extender from Bravo Communications an pushed
RS-232 past 1,000 feet with no problems (other than lightning damage).  The
boxes are about $44 each and have RJ-45's as well as DB-25's.  We have had
problems with the DTC16iX's flagging the ports as bad when we use the level
5 UTP wire for serial RS-232.  As long as we don't have a powerfail,
otherwise we have to unplug the wires from the ports when the DTC re-boots.
 
 
>classics to ix machines but have retained RS-232 connectivity
>between their terminals and DTC's.
>
>We are in the process of migrating from a series 70 to a 928. On
>the 70 we were able to run terminals, using twisted pairs, over
>extensive distances of 500-800 ft. This was at 9600 baud without
>any multiplexors or line drivers.

ATOM RSS1 RSS2