 On 9/10/2010 6:15 PM, Michael Anderson wrote:
> My point, but I hit send too fast, was that even running half-duplex would
> not stop any PCLINK2 packets. My guess is (not being there to actually
> see) the user is connected using Telnet. If you connect using NSVT it
> should work if you have opened up the appropriate ports in your firewall.
> I don't recall off-hand what port those are, but they're easy enough to
> lookup.

A universal workaround for Reflection is to go in the file transfer configuration, WRQ
tab, and set "fast file transfer" to "never".

That does an in-band transfer rather than mess with the external data channel and
potential firewall issues.

Unless you're transferring huge files it won't make that much difference either way.