Re:
> We use this to send out signatures, macros, fonts and what ever. You have
> to do it this way because through the spooler the max line of bytes you
can
> send without a new line / record separater is 1008B because spool files
are
> 1008B Variable ascii.
True enough. Or you can specify carriage control option %320 and the spooler
will suppress the CR/LF. The effect is you can string as many characters
together as needed without regard to the 1008b byte limit. Here is the exact
COBOL code I use to download a macro that is stored as 80 byte records on an
MPE system to a Laser Printer.
CALL INTRINSIC "FWRITE" USING SIGMACRO, SIG-RECORD,
\%50\, \%320\.
Doug.
Doug Werth Beechglen Development Inc.
[log in to unmask] Cincinnati, Ohio