Hello (this is a long one please bare with me): Is anyone out there familiar with a Bus-Tech Datablaster??? We currently have this set up between our Mainframe and HP 3000/997/500 when we do a 'blast' from the Mainframe to the HP it is painfully slow - we are in a quandry we have to pass a 18,000,000 record file from the Mainframe to the HP and we are looking for ways to get this process to work faster. Unfortunately there are no FTP capabilities on the Mainframe. So we are stuck with the datablaster. I have been trying a multitude of options, and my mainframe people keep telling me if I can increase my 'blocking factor' the process should go faster, I keep explaining to them that the HP doesn't really care about blocking factor. After more discussion, I was told to set my REC= to the blocking factor on the Mainframe; ok, I can do that, of course what happens next is 'EXTENT SIZE EXCEEDS MAXIMUM' if I don't use the DISC= on my FCOPY the command works, but defaults to the 1023 file size. I've included the JCL from the job that runs on the HP, this runs simultaneously with a job on the Mainframe to get the file transferred. If anyone knows anything, well you will be helping a truly frazzled human being! Thanks, Ceceil Barbarino HP Job: !JOB CBCONV2,MGR.SGAII;OUTCLASS=LP,1 !COMMENT *** ONE SHOT CONVERSION FILE BLAST ROUTINE **** !COMMENT TRANSFER OF FILES AS IT IS BEING TRANSLATED !COMMENT FROM EBCDIC TO ASCII !COMMENT This process is using the mainframe block size !COMMENT as the record length. !TELLOP !TELLOP MAKE SURE THE MAINFRAME PROCESS IS STARTED !TELLOP !TELLOP !PURGE CBCONV3.CBARBAR1 !FILE BLAST;DEV=40;REC=-32618,1,F,ASCII !BUILD CBCONV3.CBARBAR1;REC=-32618,1,F,ASCII;DISC=10000000 !FCOPY FROM=*BLAST;TO=CBCONV3.CBARBAR1 !TELLOP !TELLOP BLAST PROCESS COMPLETE. !TELLOP !EOJ ______________ Mainframe: