Therm-O-Link wrote:
SNIPPED

> So, the question (finally!) is "Can I have an unconnected "T" on
> a 10Base2 network segment or not?"  My experience here tells me
> the answer is No, but I've had two experts tell me Yes, so what
> do you think?

Donīt ask me why or for any details. But you can. When we removed one of 
our DTCs from the backbone, we only disconnected its "T" and left the "T" 
unconnected in the segment until we finally did a complete restructuring 
of the backbone - AND IT WORKED!

Cheers,

Friedrich

> 
> Jim Phillips                            Manager of Information Systems
> E-Mail: [log in to unmask]      Therm-O-Link, Inc.
> Phone: (330) 527-2124                   P. O. Box 285
>   Fax: (330) 527-2123                   Garrettsville, Ohio  44231

-- 
________________________________________________________________________
     _/_/_/_/  _/_/_/_/ _/   _/ _/    _/  Oest. Kreditversicherung AG
    _/    _/  _/       _/ _/    _/   _/   Friedrich Harasleben 
   _/    _/  _/_/_/   _/_/      _/  _/    e-mail: [log in to unmask]
  _/    _/  _/       _/  _/     _/ _/     fax   : +43 1 51554 50 300
 _/_/_/_/  _/_/_/_/ _/    _/    _/_/      phone : +43 1 51554 300
________________________________________________________________________