>[BUG report] > >The BASIC/V intriniscs for SNA/IMF have problems on MPE/iX 5.0 (push release >including powerpatch C.50.02). > >The BOPEN3270(...) call fails with error code = 26 which means something >about a parameter address out of bounds. I don't know yet if any, or all, >of the other BASIC/V intriniscs also have errors or not. > >Please note that HPRC was able to establish a PASSTHRU connection so they >thought that IMF was OK. This problem has been esclated within the HPRC >so lets see how soon it is resolved, the 'lab' is in India. > >[end BUG report] ========================================================================== And the solution is: The set of intrinsics, without a leading B, were upgraded to support BASIC/V as of release MPE/XL 2.2 but it was never documented. In release MPE/iX 5.0 HP decided to drop the B..., BASIC/V intrinsics, but it was never documented in the SNA/IMF Programmers Reference Manual. Our client is testing new versions of the interface pgms on release MPE/iX 4.0. Yes the client had to backout the 5.0 upgrade because the interface is mission critical. Out next step is to test the interface pgms on a loaner machine running 5.0, probably next week. More when I know more. ###################################################################### # Phil Wehrman ADAC HealthCare Information Systems # # [log in to unmask] 540 Alder Drive # # Pgmr Analyst/System Manager Milpitas, CA 95035 # # Ph # (408) 321-9100 x3025 FAX # (408) 577-1707 # ######################################################################