Subject: | |
From: | |
Reply To: | VANCE,JEFF (HP-Cupertino,ex1) |
Date: | Wed, 17 Nov 1999 17:39:14 -0700 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
> I got almost the exact same message the other day and it
> turned out that COMMAND.PUB.SYS was full. I solved my problem by
> building a new file with twice the capacity, copying the contents
> of COMMAND.PUB.SYS into it, then renaming the old COMMAND.PUB.SYS
> and changing the new file to COMMAND.PUB.SYS.
...
> :SHOWCATALOG
> MISSING MSG. SET=2. MESSAGE=70.
> GENMSG CALLER STATUS: %101000 DELTA-P: %177777
> GENMSG CALLER+1 STATUS: %140037 DELTA-P: %040000
Any time you see this type of message it is a bug in MPE and
an SR needs to be created to track the defect. We view these
types of defects as serious since they prevent diagnosis of
problems. I looked in catalog.pub.sys and it is *possible* that
this could have been error 10070, which is a UDC parser error:
Encountered an unexpected UDC syntax token. (CIERR 10070)
But might not be...
If you build a larger file and the problem vanishes then we
have at least 2 bugs here.
Jeff Vance, CSY
|
|
|