At 10:37 AM -0400 10/19/99, [log in to unmask] wrote:
>Does the client have a backup of the SL in question? If so, restore it to
>another directory, delete other miscellaneous entries with :SEGMENTER and
>place SL in PUB or <Group> and alter run of program with ;LIB=G or ;LIB=U
>(not sure of last item) and the old CM program will find the code in the
>group or user library.
;LIB=G Look for library in the group where the program resides
;LIB=P Look for library in the PUB group of the account where program resides
;LIB=S Look for library in PUB.SYS (the default)
If you use P, it checks PUB.ACCT first, and then PUB.SYS
If you use G, it checks GROUP.ACCT, then PUB.ACCT and finally PUB.SYS
Barry Lake [log in to unmask]
Allegro Consultants, Inc. www.allegro.com