HP3000-L Archives

September 1999, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Mario Tremblay <[log in to unmask]>
Reply To:
Mario Tremblay <[log in to unmask]>
Date:
Tue, 28 Sep 1999 11:11:44 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (43 lines)
This is quite possibly the problem when we are trying to print to a network
printer and the network is not up or starting (timing issue).  This problem
is fixed with the latest NST patch: NSTFDD8 (originally fix in NSTFD82
reported in SR: 5003437582).

Of course reading the memory dump could confirm this or reveal something
else.

Regards,

Mario.


Michael D. Hensley wrote in message ...
Steve Hammond asked:

> System abort 725, subsystem 122
> Secondary Status info=-55, Subsys 107
> System Halt 7 $02D5
>
> Any hints? Response Center seems to be having severe phone problems, so I
am
> waiting for a callback.

Hints:

:debug
DEBUG/iX C.16.01

HPDEBUG Intrinsic at: a.00a3f064 hxdebug+$e4
$1 ($71) nmdebug > =errmsg(#725,#98)
'The port's server caused an unexpected escape.'
$2 ($71) nmdebug > =errmsg(#32765,#122)
'Port (IPC) Facility'
$3 ($71) nmdebug > exit

Someone needs to look at the memory dump for more info.

---
Michael D. Hensley       | mailto:[log in to unmask]
Allegro Consultants Inc. | Visit scenic http://www.allegro.com
408/252-2330             | "Support Bill of Rights Enforcement"

ATOM RSS1 RSS2