John writes:
> > The workaround was to go to File/TransferSetup/Protocol and
> > select Doug Werth's "HP 3000 over X.25" (instead of "HP 3000 over modem").
> >
> > This changed the following flags:
...
> > TRANSMIT_PACING XON/OFF (vs. none)
...
> Can you find in File Transfer a transfer link setting. I know
Yes, but it is of no use. The "no host response" was a tipoff that
the problem had nothing to do with the file *data* (indeed, a subsequent
test showed that the immediate lack of response comes before any attempt
to look at the file's data)...but something earlier in the sequence.
That said, yes...7-bit will often get you past some datacom problems.
thanks,
--
Stan Sieler [log in to unmask]http://www.allegro.com/sieler.html