HP3000-L Archives

March 1999, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Andreas Schmidt <[log in to unmask]>
Reply To:
Date:
Thu, 11 Mar 1999 13:18:10 +0100
Content-Type:
text/plain
Parts/Attachments:
text/plain (62 lines)
Hi Bryan, this is strange because HP does no longer support vt3k as far as
I know.

But a colleague of mine, responsible to migrate to IT/O OpC 4.x advised me
to check the Release Notes. And here you can read:

If you have any MPE agents you will not be able to use the MPE tools vt3k
block mode and type ahead mode.
Solution: on mgt server edit the file
/etc/opt/OV/share/registration/C/terminal and remove all occurences of the
following lines:
/** Remove comments if you have vt3k on HPUX 10 **
** Remove comments if you have vt3k on HPUX 10 **/
This uncomments the vt3k actions and makes the tools available for use. The
applications will work the next time you start the ITO GUI.

He also advised me to search the docs under http://www.docs.hp.com and
under the IT/O section under the normal hp web presence.

I can not add any experience here because we're still under ITO 3.x
But now we know that we have to become very carefully to update the agents
on MPE. Thanks for sharing this, and please keep me informed of the final
solution.

Best regards,
Andreas Schmidt, CSC, Germany





[log in to unmask] on 03/10/99 05:09:00 PM

To:   Andreas Schmidt/HI/CSC
cc:
Subject:  IT/Operations client installation on MPE/iX




  TO: SCHMIDA / xebh
                      O=email; C=ww; A=?; P=dupont;



Andreas,
I know you have some experience with ITO and MPE so I hope you don't
mind my sending you an email to ask a (hopefully) simple question.  I
am attempting to install the MPE agent for the first time and am having
trouble.  We have ITO 4.03 and MPE 5.5 and the agent installation
fails.  We receive an error message from one of the vt3k_* scripts
during the installation.  Have you encountered similar problems?  Also,
the installation seems to skip a step.  The script that fails is one
that should run after the account/group/user is created on the 3K yet
that script (vt3k_opcinst) never runs.  Any direction you might be able
to provide would be appreciated (and publicly recognized on the
hp3000-l <g>).  I probably should mention that we are running freevt3k
on the Unix side ( don't think this matters).
Bryan Greenberg
Interstate Brands Corporation
[log in to unmask]