Brad wrote:
> I'm trying to use the clock intrinsic (in Cobol) to generate a number
> that I can use for unique file names but I can't figure out what the
> clock intrinsic is giving me. The intrinsics manual says I should get
> Hour, Minute, Seconds and Tenths of seconds.
The problem here is not what the CLOCK intrinsic is returning, but the
accessibility of bit-maps to COBOL. The CLOCK intrinsic returns a
bit-mapped timestamp. Unfortunately, it is not easily accessible in
COBOL.
Personally, I would prefer to use the variables returned from the
"CURRENT-DATE" function under COBOL '85 ($CONTROL POST85 option), but if
you really need to do this under COBOL '74 try the following code...
In working storage, add the following fields:
15.41 01 WS-CLOCK-RET.
15.42 05 WS-CLOCK-NUM PIC S9(9) COMP VALUE ZERO.
15.43 01 WS-CLOCK-DSPLY PIC -9(9).
15.44 01 WS-HOUR.
15.45 05 FILLER PIC X VALUE LOW-VALUES.
15.46 05 FILLER PIC X.
15.47 01 FILLER REDEFINES WS-HOUR.
15.5 05 WS-HOUR-9 PIC S9(4) COMP.
15.55 01 WS-MIN.
15.6 05 FILLER PIC X VALUE LOW-VALUES.
15.65 05 FILLER PIC X.
15.7 01 FILLER REDEFINES WS-MIN.
15.75 05 WS-MIN-9 PIC S9(4) COMP.
15.8 01 WS-SEC.
15.85 05 FILLER PIC X VALUE LOW-VALUES.
15.9 05 FILLER PIC X.
15.95 01 FILLER REDEFINES WS-SEC.
16 05 WS-SEC-9 PIC S9(4) COMP.
16.001
16.002 01 WS-T-FILENAME.
16.003 05 FILLER PIC X(01) VALUE "F".
16.004 05 WS-T-HOUR PIC 99.
16.005 05 WS-T-MIN PIC 99.
16.006 05 WS-T-SEC PIC 99.
16.05
In the procedure division, add...
24 CALL INTRINSIC "CLOCK" GIVING WS-CLOCK-NUM.
24.1 MOVE WS-CLOCK-NUM TO WS-CLOCK-DSPLY.
24.2 MOVE WS-CLOCK-RET(1:1) TO WS-HOUR(2:1).
24.3 MOVE WS-CLOCK-RET(2:1) TO WS-MIN(2:1).
24.4 MOVE WS-CLOCK-RET(3:1) TO WS-SEC(2:1).
24.5 DISPLAY "Current time: " WS-HOUR-9
":" WS-MIN-9
":" WS-SEC-9.
24.6 MOVE WS-HOUR-9 TO WS-T-HOUR.
24.7 MOVE WS-MIN-9 TO WS-T-MIN.
24.8 MOVE WS-SEC-9 TO WS-T-SEC.
24.9 DISPLAY "Generated file name: " WS-T-FILENAME.
25
Results:
BOI4C:RUN TSTDATEP.MMSPRG
Current date: MON, JAN 18, 1999, 1:39 PM
Current time: +0013:+0039:+0044
Generated file name: F133944
Conversion option? >> //
END OF PROGRAM
BOI4C:
Glenn
--
______________
| Navigators | Under contract to Hewlett-Packard ISG (Greeley, CO)
| |) |
| | ) | Glenn J. Koster, Sr. [log in to unmask]
| | ) | Managed Business Solutions http://www.mbsnav.com
| | ) | 214 S. College, Suite 201 970 350-5337
| |---- | Fort Collins, CO 80524 970 224-1016
| ============ |
| \__________/ |
| of Change | aka: [log in to unmask]
|______________| home: http://members.aol.com/MichiTex
|
|
|