Glenn writes:
>
> This past weekend we upgraded to the latest patch level of MPE/iX 5.5.
> At the same time we upgraded to a newer patch of MPEX. Now we have the
> problem again - kind of. If we use TimeMachine to set the date to
> 2/29/2000, MPEX aborts (on a call to DATEBUILD - invalid parameter).
> However, if we actually set all of the appropriate machine clocks to
> 2/29/2000 (with SETCLOCK), everything is fine. All other Y2K dates work
> fine under both scenarios.
...
> MPEX. My initial reactions aside, I suspect TimeMachine...
>
> BTW: We went to release 27N80324 of MPEX - which is supposed to be a
> Y2K compliant version.
MPEX 27N80324 works fine with *HourGlass*, naturally :)
(HourGlass 2000 for the HP 3000 is the *ONLY* product to intercept
*ALL* date/time requests!)
NOTE: since we don't know what MPEX command you were doing, the following
example might not be sufficient for you...sorry 'bout that!
:showtime
WED, OCT 28, 1998, 12:22 PM
:
:hgdate 1/1/2000
Welcome to HourGlass 2000 for the HP 3000!
Version 98Z
Date/time after alter: 2000-01-01 @ 12:22:51.9
SAT, JAN 1, 2000, 12:22 PM
:
:showtime
SAT, JAN 1, 2000, 12:22 PM
:
:mpex
MPEX/3000 27N80324 (c) VESOFT Inc, 1980 6.0 03:04570 For help type 'HELP'
%=today
00/01/01
%=dateyear (today)
0, $0, %0, "...."
%= dateyear (datebuild (2027,1,1))
27, $1B, %33, "...."
END OF PROGRAM
:
--
Stan Sieler [log in to unmask]
http://www.allegro.com/sieler.html
|