HP3000-L Archives

September 1998, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Gilles Schipper <[log in to unmask]>
Reply To:
Gilles Schipper <[log in to unmask]>
Date:
Tue, 8 Sep 1998 21:50:58 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (49 lines)
At 10:11 AM 98/09/08 -0500, you wrote:
>Well, apparently if you're going to cut an SLT on a DDS-3 drive, you need
>to use a DDS-3 tape.  When I tried again using DDS-3, everything now seems
>to work as expected.
>
>So, let this be a warning to the rest of you -- just because you can
>CHECKSLT it, doesn't necessarily mean you can boot from it!
>

If that's really the case, it's scary.

Obviously, it must be true that you can boot from a factory SLT tape which
is sent on 60 meter DDS 1 format - otherwise, how would one upgrade MPE/iX.

So, if Jon's conclusion is correct, those creating SLT's on, say, 120 DDS2
tapes are in for a rude shock if ever dependant on that SLT in an INSTALL
situation.

I sure hope that's not true.

I've seen this problem before - and it was related to the number of devices
on the same channel. By simply turning the power off the uninvolved
devices, which happened to be other external tape devices, the problem was
solved.

Currently, I'm experiencing a similar problem with another customer. Cannot
boot from factory SLT - but CAN boot from SLT created by the tape drive on
the system. Don't have a resolution yet - but I suspect some kind of
hardware problem. The tape drive (1504B) has already been replaced once,
without solving this problem - and will be replaced again this week.

I can say that this particular 918 has an old version of the PDC (version
1.2) which renders the MAPPER function of ODE inoperable. This is SUPPOSED
to be the only issue with respect to PDC 1.2.  Perhaps. I'll know more
later and report back.

I sure hope that creating an SLT tape on a DDS3 drive on other than 125
meter tapes does NOT result in an unbootable tape.


---------------------------------------------------------------------------
Gilles Schipper
GSA Inc.
HP3000 & HP9000 System Administration Specialists
300 John Street, Box 87651   Thornhill, ON Canada L3T 7R4
Voice: 905.889.3000     Fax: 905.889.3001
Internet:  [log in to unmask]
---------------------------------------------------------------------------