We've been having problems with a serial printer dropping spool. 
When I reset the DTC I get the following:

DTC   3

Card   SIC/SNP type        Card test status      Ports (Good or x:bad)
                                                 0123 4567
---- -------------------   ------------------    ---------------------
 2 (not installed)          
 1 TIO RS-232 Direct       OK                    GGGG GGGG 
 0 TIO RS-232 Direct       PORT 0 BAD            xGGG GGGG 

Does this look like a bad DTC?  Or a bad card?  I'm wondering about 
this because the printer on Port 0 works.  It's the printer on Port 
1 that is giving us problems.

Jim Phillips                            Manager of Information Systems
E-Mail: [log in to unmask]      Therm-O-Link, Inc.
Phone: (330) 527-2124                   P. O. Box 285
  Fax: (330) 527-2123                   Garrettsville, Ohio  44231