Subject: | |
From: | |
Reply To: | |
Date: | Thu, 20 Aug 1998 09:23:23 -0800 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
The DSEM option is interesting. I hadn't heard of it before. Does anyone know
why it should be an option; that is, is there a reason why one would disable
it?
Jim
> Importance: Normal
> Date: Thu, 20 Aug 1998 08:40:57 -0700
> Reply-to: [log in to unmask]
> From: Michael L Gueterman <[log in to unmask]>
> Subject: Re: "SUB-DATABASES"
> To: [log in to unmask]
> I haven't looked at the Communicator article yet, but could
> it possibly be talking about the use of the 'DSEM' setting in
> DBUTIL? If so, then what this means is that within any Image
> database, all datasets that are logically related (via set paths)
> are considered an atomic unit when placing a lock on the
> associated master dataset. If a dataset that is not part of that
> unit, then the lock will not affect it (as it would have in the
> past since all masters went through a single semaphore).
> For most databases, this could increase performance in a heavy
> update environment where multiple datasets are being updated by
> different processes simultaneously. This assuming they are not
> part of the same "sub database". The performance increase would
> come by virtue of not having to wait on a lock that really wasn't
> necessary in that circumstance anyway.
>
> Regards,
> Michael L Gueterman
> Easy Does It Technologies
> Allaire Alliance Partner
> email: [log in to unmask]
> http://www.editcorp.com
> voice: (888) 858-EDIT -or- (509) 943-5108
> fax: (509) 946-1170
> --
>
> > -----Original Message-----
> > From: HP-3000 Systems Discussion [mailto:[log in to unmask]]On
> > Behalf Of Leonard Berkowitz
> > Sent: Thursday, August 20, 1998 8:23 AM
> > To: [log in to unmask]
> > Subject: [HP3000-L] "SUB-DATABASES"
> >
> >
> > What does this mean and where can I read about it? This term
> > is used in the
> > Scalability section under TurboIMAGE/XL Enhancements in the
> > 5.5 Express
> > Communicator.
> >
> > ========================
> > Leonard S. Berkowitz
> > mailto:[log in to unmask]
> > phone: (617) 972-9400 ext. 3250
> > fax: (617) 923-5555
> >
> > Tufts Health Plan - Waltham Ma. 02154
> >
>
Jim Kramer /Lund Performance Solutions
Director of Research and Development
phone: (541) 926-3800 fax: (541) 926-7723
email: [log in to unmask] home: [log in to unmask]
http://www.lund.com
|
|
|