At 12:35 18.08.98 -0700, John wrote:
>On DTC connections, some combination of ABORTJOB, ABORTIO, and, if all
>else fails, a reset of the port either through TERMDSM or OPENVIEW
>DTCMGR has always worked for me. [Well, at least since MPE/iX 5.0.]

In addition to reset the DTC port (either through TERMDSM or the
OpenView DTC MGR, depending on whether host based or PC based DTCs),
it's also sometimes helpful to perform a RESET on the LDEV from
inside SYSDIAG TERMDSM. (Reset port and reset LDEV are different).

Lars.