Subject: | |
From: | |
Reply To: | |
Date: | Mon, 8 Jun 1998 14:23:12 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Just for the sake of asking, did you follow the respective steps in your
PowerPatch update to run the NMMGRVER program and then later stream the
JCONFJOB.NET.SYS job, then stop/re-start your network services?
>----------
>From: Li-Elguera, Fernando[SMTP:[log in to unmask]]
>Reply To: Li-Elguera, Fernando
>Sent: Monday, June 08, 1998 12:10 PM
>To: [log in to unmask]
>Subject: Problem with MPE/iX PP3
>
>Hello all:
>
>One our main clients have , one HP3000/957 and one HP3000/948 both with
>MPE.iX 5.5 and PowerPatch3 . Both are connected to the backbone with
>Lanic Cards, also both HP3000s are connected via Modem Patton through
>PSI cards in a connection Point to Point .
>
>After the installation of PowerPatch 3 , when I want down the Network
>Services with the command:
>
> NETCONTROL STOP
>
>The following message appears in the console of operator:
>
> SYSTEM ABORT 725 from Subsystem 122
> Secondary Status:Info= -31 , Subsys = 107
> System Halt 7, $02D5
>
>My Response Center recommended to me ,that install PowerPatch4 , I
>installed it , the installation is Ok, but the same message appears when
>I want down the Network Services.
>
>Has anybody had or still has the problem.
>
>
>Thanks in advance.
>
>
>Fernando Li-Elguera
>
>Technical Support
>System Manager
>Datalink S.A.
>
>e-mail: [log in to unmask]
>
|
|
|