HP3000-L Archives

January 1998, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
Date:
Mon, 26 Jan 1998 09:00:46 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (21 lines)
Russ Kahler wrote:

>I am attempting to set up the PAGER utility from telamon inc. on my HP
>928 running MPE/ix 5.5. I am using a Practical Peripherals 14.4
>modem. I have been using the information posted by Ed Milner ( "Modem
>setup,paging, HP3000 solution " dated 4/21/97) as a guide. However,
>when I try to use the program to dial out to a pager, it comes back
>with this error message:

>Intr: FCONTROL(11,$012C)

Russ:

Use 30, not 300, for the speed parameter.  PAGER doesn't do any edit
checking on the speed parameter.  (It will sometime in the next 10
minutes, though.)  The value has to be specified in CPS, not BPS.

------------
Randy Medd
Telamon, Inc.

ATOM RSS1 RSS2