Subject: | |
From: | |
Reply To: | |
Date: | Mon, 26 Jan 1998 09:00:46 -0800 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Russ Kahler wrote:
>I am attempting to set up the PAGER utility from telamon inc. on my HP
>928 running MPE/ix 5.5. I am using a Practical Peripherals 14.4
>modem. I have been using the information posted by Ed Milner ( "Modem
>setup,paging, HP3000 solution " dated 4/21/97) as a guide. However,
>when I try to use the program to dial out to a pager, it comes back
>with this error message:
>Intr: FCONTROL(11,$012C)
Russ:
Use 30, not 300, for the speed parameter. PAGER doesn't do any edit
checking on the speed parameter. (It will sometime in the next 10
minutes, though.) The value has to be specified in CPS, not BPS.
------------
Randy Medd
Telamon, Inc.
|
|
|