Scott Petersen <[log in to unmask]>
Reply To:
Scott Petersen <[log in to unmask]>
Date:
Tue, 16 Dec 1997 11:02:45 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (23 lines)
Several weeks ago, there was a question regarding the running of MM3000
version a.09.10 on MPE/iX 5.5.

The simple answer is YES!

The real problem is with the Application Tools.  In order run run the
Manufacturing and Financial Applications successfully on MPE/ix 5.0 or
later you need to upgrade to version C.00.00I of tools.

To determine the version of tools you need to:
        RUN VERSIONP.SYSPGM.<toolsacct>;LIB=G

This will respond with your version of tools.

In addition to the problem with tools, you need to begin the planning the
migration to a supported Y2K version of the application.

Thanks Scott.