HP3000-L Archives

September 1997, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Bernard Clalüna <[log in to unmask]>
Reply To:
Bernard Clalüna <[log in to unmask]>
Date:
Fri, 26 Sep 1997 10:40:38 GMT
Content-Type:
text/plain
Parts/Attachments:
text/plain (75 lines)
"Dr. Ferenc Nagy" <[log in to unmask]> wrote:
>Dear Mr. Claluna, Gentle list members:
>
>I wanted to write large files (Eugene Volokh's book from the VECSL
>account) on a local printer without generating a big spoolfile or
>transferable file.  I tried to use logging via the "[esc]&oCLOG..."
>commands from a Pascal program copying the files from the disk to the
>terminal. 
>The text was not logged on the printer.
>
>The essence of the operation is summed in the test files. 
>I expected that the "Print this!" and "Print that, too!" lines 
>would printed on my loocal Laserjet printer, if I execute
>:COPY FROM=TESTLOG;TO=
>under Minisoft92 and AdvanceLink, respectively.
>Instead, I got under Minisoft 92 "OFF could not be executed".
>-------TESTLOG.S92-------------
>Test of LOG command
>&oCCLOSE PRINTER
>&oCOPEN PRINTER
>&oCLOG
>Print this!
>&oCOFF
>Do not print that!
>&oCLOG
>Print that, too!
>Page eject:
>
>&oCOFF
>&oCCLOSE PRINTER
>Do not print that, either!
>-----------TESTLOG.ADV---------------------
>est of LOG command
>^[&oCLOG OFF
>^[&oCLOGFILE "PRN"
>Print this!
>^[&oLOGFILE OFF
>Do not print that!
>^[&oCLOGFILE "PRN"
>Print that, too!
>Page eject:
>^L
>^[&oCLOGFILE OFF
>Do not print that, either!
>------------------------------------------
>Who sees the error?
>                       TIA
>
> 
>                                             Frank
>
>  |\   /~ ~~|~~~ Family : NAGY; first name : FERENC; title : Ph. D.
>  | \  |    |    Institute of Isotopes of the Hungarian Academy of Sciences
>  |  \ |   -+-   HUNGARY-1121 BUDAPEST Konkoly-Thege M. ut 29,(1525 Bp. POB 77)
>  |   \|    |    [log in to unmask]  (36-1)-395-9123 Fax

Dear Frank,

The answer is easy:
OFF is not a MiniSoft Script Command by itself, it is a parameter to the LOG
command.
The correct syntax therefore is:
        LOG OFF

PS. You can reach me on the Internet, too: 
        [log in to unmask]

Bernard Clalüna, Technical Support
*********************************************************************
* MiniSoft Marketing AG                   [log in to unmask]  *
* Papiermühleweg 1                        [log in to unmask] *
* CH-6048 Horw                            Tel. +41 (0)41 340 23 20  *
* Switzerland                             Fax  +41 (0)41 340 38 66  *
*********************************************************************

ATOM RSS1 RSS2