Well, I finally got the DTC to work over frame relay. My troubles had
nothing to do with the frame and network hardware and everything to do
with human error.
Error #1: The DTC LAN Address internally was not the same as the one
posted on the outside of the unit. See my previous post about how to
verify and change the LAN Address.
Error #2: I had slot 0 configured as 2 printers and 6 terminals using
a known, good terminal profile (in NMMGR). I would have bet money that
I used the same terminal profile for slot 1, but nay, I used some other
profile that was configured as modem instead of direct connect. This
was my fault. Mea culpa.
Jim Phillips Manager of Information Systems
Voice: (915) 860-9933 Therm-O-Link of Texas, Inc.
Fax: (915) 860-9936 1295 Henry Brennan
Email: [log in to unmask] El Paso, Texas 79936