HP3000-L Archives

July 1997, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Ken Vickers <[log in to unmask]>
Reply To:
Ken Vickers <[log in to unmask]>
Date:
Tue, 22 Jul 1997 11:31:09 +0100
Content-Type:
text/plain
Parts/Attachments:
text/plain (42 lines)
>Return-Path: <[log in to unmask]>
>Date:         Tue, 22 Jul 1997 11:50:16 -0700
>Reply-To:     Friedrich Harasleben <[log in to unmask]>
>Sender:       HP-3000 Systems Discussion <[log in to unmask]>
>From:         Friedrich Harasleben <[log in to unmask]>
>Organization: OEKV
>Subject:      POSIX vs. NETWARE time
>To:           [log in to unmask]
>
>Hi,
>
>does anybody know why the TIME stamp for entries in a NETWARE/iX print
>queue as shown under POSIX (ls -l q*) and as shown under NOVELL (dir )
>are not the same.
>
>e.g.
>
>POSIX says: ..... Jul 22 00:36 job_116.que
>
>DIR   says: JOB_116.QUE ......... 22.07.97  11:36
>
>HOW COME?
>
>TIA,
>
>Friedrich
>

Hi Friedrich,

Could it be your Posix timezone (TZ) needs setting?

Are you nearly daylight saving?

Ken Vickers

Manager LINKWAY Development and Support
Computing Solutions Limited

TEL +44 (0) 1905 794400
FAX +44 (0) 1905 794464