Subject: | |
From: | |
Reply To: | |
Date: | Tue, 15 Jul 1997 10:11:17 +0200 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
What about this discfree output (called df5):
XENBH8#df5
DF5.A.00.02 -- Enhanced DISCFREE 5 for System & User Volumes --
TUE, JUL 15, 1997, 10:05 AM
All measurements are in sectors.
All percentages are relative to the DEVICE size.
XENBH8 | Configured | In Use | Available |
-----------+-------------------+-------------------+-------------------+
MPEXL_SYSTEM_VOLUME_SET
Device | 95294736 | 48119952 ( 50%) | 47174784 ( 49%) |
Permanent | 71470944 ( 74%) | 34716928 ( 36%) | 36754016 ( 38%) |
Transient | 71470944 ( 74%) | 13403024 ( 14%) | 46531776 ( 48%) |
DISKDUMP_VOLUME_SET
Device | 20958272 | 20158992 ( 96%) | 799280 ( 3%) |
Permanent | 20958272 (100%) | 20158992 ( 96%) | 799280 ( 3%) |
Transient | 20958272 (100%) | 0 ( 0%) | 799280 ( 3%) |
UV_SET1
Device | 49983168 | 21110016 ( 42%) | 28873152 ( 57%) |
Permanent | 49983168 (100%) | 21110016 ( 42%) | 28873152 ( 57%) |
Transient | 49983168 (100%) | 0 ( 0%) | 28873152 ( 57%) |
UV_SET2
Device | 183271616 | 115103952 ( 62%) | 68167664 ( 37%) |
Permanent | 183271616 (100%) | 115103952 ( 62%) | 68167664 ( 37%) |
Transient | 183271616 (100%) | 0 ( 0%) | 68167664 ( 37%) |
UV_SET3
Device | 233254784 | 169096976 ( 72%) | 64157808 ( 27%) |
Permanent | 233254784 (100%) | 169096976 ( 72%) | 64157808 ( 27%) |
Transient | 233254784 (100%) | 0 ( 0%) | 64157808 ( 27%) |
UV_SET4
Device | 83305280 | 58765056 ( 70%) | 24540224 ( 29%) |
Permanent | 83305280 (100%) | 58765056 ( 70%) | 24540224 ( 29%) |
Transient | 83305280 (100%) | 0 ( 0%) | 24540224 ( 29%) |
UV_SET5
Device | 216593728 | 115362752 ( 53%) | 101230976 ( 46%) |
Permanent | 216593728 (100%) | 115362752 ( 53%) | 101230976 ( 46%) |
Transient | 216593728 (100%) | 0 ( 0%) | 101230976 ( 46%) |
Base is a COBOL program written some years ago (1994) but still working
and enhanced to cover more than 100 devices in 1996.
If somebody is interested in the code please let me know.
--
Best regards, Andreas Schmidt
CSC GIU-Europe
Technical Services
61343 Bad Homburg, DuPont-Strasse 1, Room 1-346
Phone: 06172-87-2117 Fax -2108 DUCOM x951-2117