HP3000-L Archives

June 1997, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Mark Bixby <[log in to unmask]>
Reply To:
Date:
Wed, 25 Jun 1997 17:03:28 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (32 lines)
It sounds like the HPRC already knows about the PP2 problems I reported
regarding Stage/iX and STORXLnn:

> Unfortunately, you have encountered 2 problems with the new Power Patch
> installations.
>
> For the stageman problem the following will complete the staging:
>
> 1.  STAGEMAN> expert on
> 2.  STAGEMAN$ COMPLETE <stage_name>
> 3.  STAGEMAN$ VALIDATE <stage_name>
> 4.  STAGEMAN$ SET <stage_name>
> 5.  START NORECOVERY will boot from this staging area.
>
> For your second problem, the job does need to have the
> CONTINUE inserted in front of the copy for STORXL51 because you will
> have either one or the other file on your tape.  You have TurboStore II
> OLB on you system, therefore, you need to have the STORXL52 file
> restored.

First the screw up that resulted in everybody getting the advanced TurboStore
functionality, then the confusing documentation, and finally an install job
that doesn't work.

I expect better quality than this from HP.
--
Mark Bixby                      E-mail: [log in to unmask]
Coast Community College Dist.   Web: http://www.cccd.edu/~markb/
District Information Services   1370 Adams Ave, Costa Mesa, CA, USA 92626-5429
Technical Support               +1 714 438-4647
"You can tune a file system, but you can't tune a fish." - tunefs(1M)