At 08:32 PM 6/9/97 -0400, [log in to unmask] wrote:
/snip

>One of the data bases was the OCS Express data base (for job
>scheduling), OCSDB.  OCSDB has Superdex indexes, and they are
>used by programs.  When it was discoverd that indexing had been
>disabled, entries had been made to OCSDB, so it was necessary to
>re-index.  The re-indexing job ran with no errors and all the correct
>messages and record counts.  SIMAINT says the indexes are there,
>just as they were before, and ADAGER finds nothing wrong with the
>data base.  However, the programs that use the indexes do not
>select any records, even for values that we can see in the data base.
>QUERY does not find any records for any values we try either.

Cecile,

Could you check to see if by chance there are any JCWs/VARs set
either before or after the attempted access which are "SI@" or
possibly "@TPI@".  If you find any, send me a note.

/jf