HP3000-L Archives

June 1997, Week 2

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Undetermined origin c/o LISTSERV administrator <[log in to unmask]>
Reply To:
Undetermined origin c/o LISTSERV administrator <[log in to unmask]>
Date:
Fri, 13 Jun 1997 13:11:26 -0700
Content-Type:
text/plain
Parts/Attachments:
text/plain (13 lines)
In article , Gilles says...
>
>At 11:48 AM 97/06/12 -0400, you wrote:
>>OK, STORE DIRECTORY stores "the accounts, groups, users, and files in
>>our system." But what about UDCs, etc.? We still need to run BULDACCT
....

UDC's are set/unset by adding/deleting entries from CATALOG.PUB.SYS
(via SETCATALOG). Therefore restoring this file from tape set all  your udc's.

One step of an MPE update is renaming CATALOG.PUB.SYS to unset
all UDC's and then at the end of the update renaming it back.