Jens von Bulow wrote:
>
> The error message on the HP3000 console was as follows.
>
> system abort 1458 from subsystem 102
> system halt 7, $05B2
>
This is the most 'generic' system abort we have in the MPE/iX OS.
It basically means that a processes encounters any kind of trap,
at a point in its execution where it is set to the critical state.
OS routines (and subsystems like networks, etc) do this per a
call to the OS internal (no Intrinsic !) routine SETCRITICAL,
with its purpose to hold of any interrupts (like e.g. a
termination interrupt from an ABORTJOB or KILL) during the
execution of a 'critical' piece of the execution.
Now if your program does not call SETCRITICAL, then one of the
OS or network procedures that your program called probably
encountered a trap. This could be due to an invalid parameter
or pointer passed to the OS routine, though mostly the latter
do a good job of parameter checking.
Generally a user mode program (unless your program uses PRIV
mode) should not be able to crash the system, so this sounds
like a case where you should involve your local Response Center.
hope this helps,
Goetz (normally @hp.com).
|
|
|