I have just done a test with a QTP run that generates a data conversion error. QTP terminates and sets the following JCW's

CIERROR = 976
JCW = FATAL3
QTP = 8
CJCW = 3

Maybe QUICK sets similar JCW's??

Tony Knowles


>Hi all,

>I am trying to solve the following POWERHOUSE related problem:

>A QDESIGN (6.19.D) is started from within a MPE batch job (with the help of >QKGO settings).
>The program transfers data from one dataset to another, doing some >conversions etc. When
>QUICK encounters a "data conversion error" the program stops running, but >does not (at least
>AFAIK) set any JCW telling me that some errors occured. As we usually >delete our STDLIST
>after jobs have completed (depending on JCW or CIERROR conditions), >nobody will know about
>the error unless some users are beginning to complain.

>Does anybody know, if there is any solution to this problem?

>TIA,

>Friedrich Harasleben