HP3000-L Archives

March 1997, Week 3

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Chris Bartram <[log in to unmask]>
Reply To:
Date:
Fri, 21 Mar 1997 12:55:53 -0400
Content-Type:
Text/Plain
Parts/Attachments:
Text/Plain (28 lines)
 In <[log in to unmask]> [log in to unmask] writes:

> At this point 'unpack' invokes MOVER version A.00.02
>
>   Unloading truck '/SYS/INSTALL/DTSEDH5A'
>   FCODE SIZE  EOF   LIMIT   ACCESS     FILENAME
>   Creating directory(ies) in path: 'AUTOPAT'
>   0     80B   1198  1198    -rw-rw---- AUTOPAT
>
>   Buffer overflow on input (non).
>
>   END OF PROGRAM

Make sure you have the "right" Mover version A.00.02. DO a

:listf mover.prvxl.telesup,2
ACCOUNT=  TELESUP     GROUP=  PRVXL

FILENAME  CODE  ------------LOGICAL RECORD-----------  ----SPACE----
                  SIZE  TYP        EOF      LIMIT R/B  SECTORS #X MX

MOVER     NMPRG   128W  FB         635        635   1      640  3  1

If your EOF's not 635, you've got the wrong version (despite the A.00.02
header). Download a new copy from Jazz.

            -Chris Bartram

ATOM RSS1 RSS2