Joe Geiser <[log in to unmask]>
Reply To:
Date:
Wed, 11 Dec 1996 13:21:45 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (38 lines)
----------
> From: Sam Knight <[log in to unmask]>
> To: [log in to unmask]
> Subject: NetIPC Error 42
> Date: Wednesday, December 11, 1996 12:49 PM
>
> We have been having several of our user sessions disconnected
with the
> following error message:
>
> ** NS/3000 NetIPC ERROR IN VT; Job: #S7839; PIN: 79; Info: 1
> - Error: 42; REMOTE NOT RESPONDING, CONNECTION CLOSED
>

Sam,

The most common cause of this is when a user accessing the 3000
from a PC using VT, closes the termulator without logging off
(ie: entering :BYE).  We get this all the time.

To allieviate this, users should log off before closing their
termulators.  This is not just limited to BS from Tymlabs, but
MS92 and Reflection as well...The 3000 is attempting to poll the
net connection, and it's not there.  After a few retries, it
closes the connection and issues the above message to the
console.

Joe

-----------------------------------------------------------------
-------------
Joe Geiser
CSI Business Solutions
[log in to unmask]
(soon to be [log in to unmask])
-----------------------------------------------------------------
-------------