I had a similar problem at a number of sites in Europe and Australia.
Many of the inexpensive pc's we were using with Relection would echo
anything sent to when they were powered off. The DTC's are designed
to echo anything they receive. This resulted in a race condition that
continued until the users arrived in the morning and turned on the
pc's. Not a good thing to happen on networks where carriers charge
for usage!
Keven Miller <[log in to unmask]> wrote:
>We had similar problems on our 70 running Reflections on serial lines.
>It appeared that with the PC off (only on some), the ATPs would see a
>CR (return) character constantly on the line.
>
>Since we had source for our app (ASK-MANMAN), we added a 0 len input
>counter which after counting to 25, we assumed a runaway session and
>terinated the process.
>
>Only trapped a few users with count of 25. :)
>--
>
>Keven Miller KC7LYD
>[log in to unmask] (Springville, Utah, USA)