Reply To:
[log in to unmask][log in to unmask], 19 Nov 1996 13:34:00 -0500646_- I ran into this problem recently. The only way you can control
the print parameters is to send the escape sequences from the hp3000
to the printer, (this will work on laserjet 4 or 5's), the following
example show the exact syntax:

FILE LPCARL4;DEV=LPCARL04,10
ECHO %-12345X@PJL DEFAULT ORIENTATION=LANDSCAPE >*LPCARL4
ECHO %-12345X@PJL DEFAULT FORMLINES=66 >*LPCARL4
ECHO %-12345X@PJL DEFAULT LPARM:PCL SYMSET=ROMAN-8 >*LPCARL4
ECHO %-12345X@PJL DEFAULT LPARM:PCL FONTNUMBER=0 >*LPCARL4
ECHO %-12345X@PJL DEFAULT LPARM:PCL PITCH=16.67 >*LPCARL4
ECHO %-12345X >*LPCARL4
RESET LPCARL4 [...]39_19Nov199613:34:[log in to unmask]
Date:
Fri, 15 Nov 1996 17:00:28 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (20 lines)
 In <[log in to unmask]> [log in to unmask] writes:

>
> For those who care, I was informed today that powerpatch 1 is out.
> Gary Jackson
> Nevada CSOS
> (916) 478-6407 - voice
> (916) 478-6410 - fax
Does powerpatch 1 have Telnet Server block mode support???