HP3000-L Archives

September 1996, Week 4

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
PETER VALIER <[log in to unmask]>
Reply To:
PETER VALIER <[log in to unmask]>
Date:
Mon, 23 Sep 1996 14:10:05 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (28 lines)
>I recall hearing about a way to reset spoolfile and job number without
>bouncing the system.  The Laser-rom search didn't indicate much.  Could
>someone direct me to the correct subsystem command or give more
>information.  We are running 5.0 on a 937 and 995.
 
 
Response:  The command to use is the setcounter command as follows:
SETCOUNTER
 
     Sets the next value of a specified resource counter, and optionally
     enables automatic rollback when a specified limit is reached.
     Duplicate values are avoided.
 
SYNTAX
 
     SETCOUNTER [COUNTER=] [ INSP    ]
                           [ OUTSP   ]
                           [ JOBNUM  ]
                           [ SESSNUM ]
                [; BASE = <num>]
                [; MAX  = <num>]
 
                [;SHOW]
 
 
Peter Valier
Misco Canada Inc