On Mon, 12 Aug 1996, Donna Garverick wrote:
> Randy Smith <[log in to unmask]> wrote:
>
> >We have had a similar problem with our boxes ever since we moved
> >to 5.0. Here's what we do to solve the problem:
>
> >1) TERMDSM the port 3 or more times
>
> ...this is changing the topic somewhat but - isn't termdsm *supposed*
> to do something? my 'alambama-humidty-rusted' brain seems to recall
> this program at least giving you a prompt for typing in commands. i
> tried running it the other day and it went straight to an end of
> program. am i missing something? - donna
>
Donna,
TERMDSM still works; it's just part of SYSDIAG now. Enter SYSDIAG at the
MPE prompt and follow its prompts to get where you want.
Don Harrington Boeing Commercial Airplane Group
(206) 931-4457 voice P. O. Box 3707 M/S 5J-34
(206) 931-9085 FAX Seattle, WA 98124-2207
[log in to unmask]