I've got a compatibility mode COBOL program that uses various intrinsic
calls (FCONTROL, FSETMODE, FDEVICECONTROL) to configure a port and read from
a digital weigh indicator attached to that port.  The program worked fine
until the system was updated to MPE/ix 5.0.  Now the FREAD intrinsic returns
a "PARITY ERROR" on every try.  Nothing else has changed.
 
Has anyone experienced a problem similar to this... and if so... any
suggestions?
 
Thanks for your help!
 
--
Bill Kimmel
[log in to unmask]