HP3000-L Archives

May 1995, Week 3

HP3000-L@RAVEN.UTC.EDU

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Martin Knapp <[log in to unmask]>
Reply To:
Martin Knapp <[log in to unmask]>
Date:
Thu, 18 May 1995 10:45:38 PDT
Content-Type:
text/plain
Parts/Attachments:
text/plain (26 lines)
Luc Sierens wrote:
 
>The thing WE are worried about is: what locking level is used by
>Powerbuilder using Image/SQL? Would it coexist happily with BBXL
>programs locking at item level? Anyone got experience with this?
 
The first thing you need to be aware of is that while you are still
on MPE/iX 4.0 you are most likely to be using ALLBASE "F" as the
IMAGE/SQL interface, and in this case there is only one kind of
locking: a full lock on the entire dataset.
 
If you are going to get into this seriously, I would recommend
upgrading to MPE/iX 5.0 before going any further.
Yours sincerely,
 
Martin Knapp
 ==========================================================================
 
Martin Knapp                             Voice:  (+44)-1689-877-933
Proactive Systems                          FAX:  (+44)-1689-891-475
Central Court                           E-Mail:  [log in to unmask]
Knoll Rise
Orpington
Kent, BR6 0JA
United Kingdom

ATOM RSS1 RSS2