Subject: | |
From: | |
Reply To: | |
Date: | Tue, 25 Oct 2022 06:12:43 -0600 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
I find doing an stmshut.diag.sys before the network is brought down prior to the shutdown can help…
Sent from my iPhone
> On Oct 24, 2022, at 3:57 PM, Tracy Johnson <[log in to unmask]> wrote:
>
> One of the old sticking points in "Spectrum" class when it first came out was it was safe to power down after it reached SHUT 4 even thought it was not complete until SHUT 6. So it applied to both HP3K and HP9K.
>
> I think SHUT 4 was completion of disc activity which made it safe. I could be wrong here so feel free to correct me.
>
> Anything after that was gravy. Just some lost bits that won't get used again anyway.
>
>
>> On 10/24/22 16:17, James B. Byrne wrote:
>> Is there a positive console confirmation when SHUTDOWN SYSTEM completes
>> (MPE/iX-7.5pp5)? If so then what is it? If not then how does one determine
>> that it is safe to cut the power?
>>
>
> --
> Tracy Johnson
> BT
>
>
>
>
>
>
>
> NNNN
>
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|