I find doing an  stmshut.diag.sys before the network is brought down prior to the shutdown can help…

Sent from my iPhone

> On Oct 24, 2022, at 3:57 PM, Tracy Johnson <[log in to unmask]> wrote:
> 
> One of the old sticking points in "Spectrum" class when it first came out was it was safe to power down after it reached SHUT 4 even thought it was not complete until SHUT 6.  So it applied to both HP3K and HP9K.
> 
> I think SHUT 4 was completion of disc activity which made it safe.  I could be wrong here so feel free to correct me.
> 
> Anything after that was gravy.  Just some lost bits that won't get used again anyway.
> 
> 
>> On 10/24/22 16:17, James B. Byrne wrote:
>> Is there a positive console confirmation when SHUTDOWN SYSTEM completes
>> (MPE/iX-7.5pp5)?  If so then what is it?  If not then how does one determine
>> that it is safe to cut the power?
>> 
> 
> -- 
> Tracy Johnson
> BT
> 
> 
> 
> 
> 
> 
> 