Tracy,
Did you do a SHOWDEV 2809? Is it spooled? I don't remember seeing the information. Documentation says:
Files which include a forms message, and which are directed to an
unspooled printer, always trigger a forms message dialog with the printer's operator.
If I remember correctly, replies can appear if FORMID or FORMS (formsmsg) changes from one spoolfile to the next.
My 0,02...
Thanks...François
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf Of Johnson, Tracy
Sent: August-07-14 9:10 AM
To: [log in to unmask]
Subject: Re: [HP3000-L] Mysterious Reply Messages on Spool Files
No one else at our two dozen locations with 800 + printers have this problem with UT700 however.
Tracy Johnson
Office (757) 766-4318
[log in to unmask]
> -----Original Message-----
> From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On
> Behalf Of krikor Gullekian
> Sent: Wednesday, August 06, 2014 8:20 PM
> To: [log in to unmask]
> Subject: Re: [HP3000-L] Mysterious Reply Messages on Spool Files
>
> It looks like it's always the same program. The output file generated
> is UT700, did something changed in that program?
>
> Just a thought
> Krikor
>
>
>
> ________________________________
> From: joseph dolliver <[log in to unmask]>
> To: [log in to unmask]
> Sent: Wednesday, August 6, 2014 2:42 PM
> Subject: Re: [HP3000-L] Mysterious Reply Messages on Spool Files
>
>
> Tracy, what does a "showdev" and a "listening" of all your printers.
> It must be coming from how they are configured. Any changes or swaps
> of printers in the recent past? Just saying. "Ioconfig" listed
> device
>
> Joe
> On Aug 6, 2014 2:23 PM, "Johnson, Tracy" <[log in to unmask]>
> wrote:
>
> > I asked about it last week to no satisfaction and console replies
> > are still coming out of the blue.
> >
> > Notice there is no forms flag (F) on the current file being printed
> > at
> the
> > top, but yet the console needs a reply. I checked the PIN and it is
> simply
> > OUTSPTJ and the parent goes to SPOOLMOM. (It must be a single Mom
> because
> > there is no SPOOLDAD.)
> >
> > I thought I could lay the blame on 3rd party utility software (the
> > kind that generates forms), but this is not a form.
> >
> > THE FOLLOWING REPLIES ARE PENDING:
> > 4:59/1016/SP#2809/IS #J2300; RE992M ON LDEV#2809 (Y/N)?
> > /SYS/PUB%>LISTSPF @;SELEQ=[DEV=2809]
> >
> > SPOOLID JOBNUM FILEDES PRI COPIES DEV STATE RSPFN OWNER
> >
> > #O501258 J2300 RE992M 8 1 2809 PRINT S
> > JBSTRM25.MMV090
> > #O501259 J2301 RE992M 8 1 2809 READY S
> > JBSTRM25.MMV090
> > #O501262 J2303 RE993M 8 1 2809 READY S
> > JBSTRM25.MMV090
> > #O503915 S267 RE993M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503917 S267 RE992M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503935 S267 RE993M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503940 S267 RE992M 8 1 2809 READY S
> NORUMK.MMV090
> > #O503942 S267 RE995M 8 1 2809 READY S
> NORUMK.MMV090
> > #O500302 J3599 UT700FR 2 1 2809 READY S F
> > MGR.STR
> > #O500304 J3599 UT700FR 2 1 2809 READY S F
> > MGR.STR
> > #O500305 J3599 UT700FR 2 1 2809 READY S F
> > MGR.STR
> > #O500306 J3599 UT700FR 2 1 2809 READY S F
> > MGR.STR
> > #O500307 J3599 UT700FR 2 1 2809 READY S F
> > MGR.STR
> > #O500324 J3599 UT700FJ 2 1 2809 READY S
> > MGR.STR
> > #O500286 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500287 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500288 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500289 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500290 J613 UT700FF 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500308 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500309 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500310 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500311 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500312 J613 UT700FR 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500330 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500331 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500332 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500333 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> > #O500334 J613 UT700FX 8 1 2809 SPSAVE S F
> OPERATOR.SYS
> >
> > INPUT SPOOL FILES OUTPUT SPOOL FILES ACTIVE = 0;
> >CREATE = 0; READY = 13; OPEN = 0;
> >DEFER = 0; SELECTED = 8; READY = 0;
> >DELPND = 0; SPSAVE = 15;
> > PRINT = 1; XFER =
> >0;
> > PROBLM = 0;
> >
> > TOTAL IN FILES = 0; TOTAL OUT FILES = 29;
> > IN SECTORS = 0; OUT SECTORS = 7888;
> >
> > OUTFENCE = 7
> > OUTFENCE = 11 FOR LDEV 6
> > OUTFENCE = 11 FOR LDEV 101
> > /SYS/PUB%>RECALL
> > THE FOLLOWING REPLIES ARE PENDING:
> > 4:59/1016/SP#2809/IS #J2300; RE992M ON LDEV#2809 (Y/N)?
> > /SYS/PUB%>REPLY 1016,Y
> > /SYS/PUB%>RECALL
> >
> >
> > Tracy Johnson
> > Business Analyst
> > Measurement Specialties, Inc.
> > Office (757) 766-4318
> > Cell (757) 755-6470
> > [log in to unmask]<mailto:[log in to unmask]>
> >
> >
> > * To join/leave the list, search archives, change list settings, *
> > * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
>
>
> >
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|