Tracy,

Did you do a SHOWDEV 2809? Is it spooled? I don't remember seeing the information. Documentation says:

Files which include a forms message, and which are directed to an
unspooled printer, always trigger a forms message dialog with the printer's operator.

If I remember correctly, replies can appear if FORMID or FORMS (formsmsg) changes from one spoolfile to the next.

My 0,02...

Thanks...François

-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf Of Johnson, Tracy
Sent: August-07-14 9:10 AM
To: [log in to unmask]
Subject: Re: [HP3000-L] Mysterious Reply Messages on Spool Files

No one else at our two dozen locations with 800 + printers have this problem with UT700 however.


Tracy Johnson
Office (757) 766-4318
[log in to unmask]


> -----Original Message-----
> From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On 
> Behalf Of krikor Gullekian
> Sent: Wednesday, August 06, 2014 8:20 PM
> To: [log in to unmask]
> Subject: Re: [HP3000-L] Mysterious Reply Messages on Spool Files
> 
> It looks like it's always the same program. The output file generated 
> is UT700, did something changed in that program?
> 
> Just a thought
> Krikor
> 
> 
> 
> ________________________________
>  From: joseph dolliver <[log in to unmask]>
> To: [log in to unmask]
> Sent: Wednesday, August 6, 2014 2:42 PM
> Subject: Re: [HP3000-L] Mysterious Reply Messages on Spool Files
> 
> 
> Tracy, what does a "showdev"  and a "listening" of all your printers.  
> It must be coming from how they are configured.  Any changes or swaps 
> of printers in the recent past?   Just saying.  "Ioconfig" listed 
> device
> 
> Joe
> On Aug 6, 2014 2:23 PM, "Johnson, Tracy" <[log in to unmask]>
> wrote:
> 
> > I asked about it last week to no satisfaction and console replies 
> > are still coming out of the blue.
> >
> > Notice there is no forms flag (F) on the current file being printed 
> > at
> the
> > top, but yet the console needs a reply.  I checked the PIN and it is
> simply
> > OUTSPTJ and the parent goes to SPOOLMOM.  (It must be a single Mom
> because
> > there is no SPOOLDAD.)
> >
> > I thought I could lay the blame on 3rd party utility software (the 
> > kind that generates forms), but this is not a form.
> >
> > THE FOLLOWING REPLIES ARE PENDING:
> > 4:59/1016/SP#2809/IS #J2300; RE992M ON LDEV#2809 (Y/N)?
> > /SYS/PUB%>LISTSPF @;SELEQ=[DEV=2809]
> >
> > SPOOLID    JOBNUM   FILEDES  PRI COPIES DEV      STATE  RSPFN OWNER
> >
> > #O501258   J2300    RE992M     8      1 2809     PRINT   S
> >  JBSTRM25.MMV090
> > #O501259   J2301    RE992M     8      1 2809     READY   S
> >  JBSTRM25.MMV090
> > #O501262   J2303    RE993M     8      1 2809     READY   S
> >  JBSTRM25.MMV090
> > #O503915   S267     RE993M     8      1 2809     READY   S
> NORUMK.MMV090
> > #O503917   S267     RE992M     8      1 2809     READY   S
> NORUMK.MMV090
> > #O503935   S267     RE993M     8      1 2809     READY   S
> NORUMK.MMV090
> > #O503940   S267     RE992M     8      1 2809     READY   S
> NORUMK.MMV090
> > #O503942   S267     RE995M     8      1 2809     READY   S
> NORUMK.MMV090
> > #O500302   J3599    UT700FR    2      1 2809     READY   S F  
> > MGR.STR
> > #O500304   J3599    UT700FR    2      1 2809     READY   S F  
> > MGR.STR
> > #O500305   J3599    UT700FR    2      1 2809     READY   S F  
> > MGR.STR
> > #O500306   J3599    UT700FR    2      1 2809     READY   S F  
> > MGR.STR
> > #O500307   J3599    UT700FR    2      1 2809     READY   S F  
> > MGR.STR
> > #O500324   J3599    UT700FJ    2      1 2809     READY   S    
> > MGR.STR
> > #O500286   J613     UT700FF    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500287   J613     UT700FF    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500288   J613     UT700FF    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500289   J613     UT700FF    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500290   J613     UT700FF    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500308   J613     UT700FR    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500309   J613     UT700FR    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500310   J613     UT700FR    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500311   J613     UT700FR    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500312   J613     UT700FR    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500330   J613     UT700FX    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500331   J613     UT700FX    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500332   J613     UT700FX    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500333   J613     UT700FX    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> > #O500334   J613     UT700FX    8      1 2809     SPSAVE  S F
> OPERATOR.SYS
> >
> > INPUT SPOOL FILES            OUTPUT SPOOL FILES  ACTIVE   = 0;                
> >CREATE   = 0;              READY    = 13;  OPEN     = 0;                
> >DEFER    = 0;              SELECTED = 8;  READY    = 0;                
> >DELPND   = 0;              SPSAVE   = 15;
> >                              PRINT    = 1;              XFER     = 
> >0;
> >                              PROBLM   = 0;
> >
> > TOTAL IN FILES   = 0;        TOTAL OUT FILES   = 29;
> >       IN SECTORS = 0;              OUT SECTORS = 7888;
> >
> > OUTFENCE = 7
> > OUTFENCE = 11 FOR LDEV 6
> > OUTFENCE = 11 FOR LDEV 101
> > /SYS/PUB%>RECALL
> > THE FOLLOWING REPLIES ARE PENDING:
> > 4:59/1016/SP#2809/IS #J2300; RE992M ON LDEV#2809 (Y/N)?
> > /SYS/PUB%>REPLY 1016,Y
> > /SYS/PUB%>RECALL
> >
> >
> > Tracy Johnson
> > Business Analyst
> > Measurement Specialties, Inc.
> > Office (757) 766-4318
> > Cell (757) 755-6470
> > [log in to unmask]<mailto:[log in to unmask]>
> >
> >
> > * To join/leave the list, search archives, change list settings, *
> > * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
> 
> 
> 
> >
> 
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
> 
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2