On 10/1/13 12:27 PM, jp928 wrote:
> Trying to get my times reset properly since a re-install 7.5
>
> I set TZ and HPPATH as manager.sys, but as soon as I logon somewhere else,
> the changes are lost....what am I missing here please?
>
> The loss of correct TZ messes up the displayed dates and times on files...
CI (Command Interpreter) variables are job/session-only in scope. That
is, they exist only for the job/session which sets them, and (aside from
the HP@ varialbles provided by the OS) they disappear when the
job/session logs off.
If you need every job/session to have certain variables, then every
job/session needs to set them. The usual way this is done is to set them
in a system-wide logon UDC.
Barry Lake