OK, I set corrected.
George, maybe you want to use the SETCLOCK command?
Hat Tip to Mark R.
-Craig
:help setdate
^
Can't find anything under this command or in table of contents.
:help setclock
SETCLOCK
Alters the system time or system time zone.
SYNTAX
SETCLOCK {DATE= date spec; TIME= time spec [;GRADUAL | ;NOW]}
{CORRECTION= correction spec [;GRADUAL | ;NOW]}
{TIMEZONE= time zone spec}
{;CANCEL}
KEYWORDS: PARMS,OPERATION,EXAMPLE
:
--- On Sat, 12/29/12, Mark Ranft <[log in to unmask]> wrote:
From: Mark Ranft <[log in to unmask]>
Subject: Re: [HP3000-L] Mpe: SETDATE Utility
To: "Craig Lalley" <[log in to unmask]>
Date: Saturday, December 29, 2012, 7:12 AM
Are you sure about that?
Mark Ranft
On Dec 29, 2012, at 8:48 AM, Craig Lalley <[log in to unmask]> wrote:
> Nope it is an MPE command.
>
> :HELP SETDATE
>
> -Craig
>
> Sent from my iPad
>
> On Dec 29, 2012, at 6:43 AM, Gilles Schipper <[log in to unmask]> wrote:
>
>> Is SETDATE part of a 3rd-party software utility ?
>>
>> Because I don't believe it's a valid MPE command.
>>
>> If so, perhaps your license for it's use has expired or it's not licensed for the N4000.
>>
>>
>>
>> At 08:54 PM 2012-12-28, George Forsythe wrote:
>>> We are trying to test Year-End activities, so I tried using the SETDATE utility.
>>>
>>> It worked fine on our small test system, 927LX running MPE/iX 6.5 -
>>>
>>> :setdate 01/01/13
>>> CURRENT-DATE: 01/01/13
>>> :
>>> :setdate reset
>>> CURRENT-DATE: 12/28/12
>>> :
>>>
>>> However, on the Production system, a N-Class-4000-400-75 System running MPE/iX 7.5, there is an issue -
>>>
>>> :setdate 01/01/13
>>> CURRENT-DATE: 01/01/13
>>> :
>>> :setdate reset
>>> An AIF:PE handler library can only be folloowed by either another AIF:PE handler library or the system libraries. (LDRERR 678)
>>> Native mode loader message 678
>>> Unable to load program to be run (CIERR 625)
>>> :
>>>
>>> Has anyone seen this issue before or know how to resolve it ?
>>>
>>> Any and all suggestions are greatly appreciated...
>>>
>>> * To join/leave the list, search archives, change list settings, *
>>> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>>
>> -------------------------------------------------------------------------------------------------
>> Gilles Schipper
>> GSA Inc.
>> HP System Administration Specialists
>> 300 John Street, Box 87651 Thornhill, ON Canada L3T 7R4
>> Tel: 416.702.7900
>> email: [log in to unmask] web: http://www.gsainc.com
>> -------------------------------------------------------------------------------------------------
>>
>> * To join/leave the list, search archives, change list settings, *
>> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|