And for the llio error -44 specifically:

   llio_hw_problem            = -44;    { This mgr's device had H/W err}
                                        { for which no other stat avail}

---- Tom Lang <[log in to unmask]> wrote: 
> The manual states:
> 
> 1557 MESSAGE SPECIFICALLY, STORE RECEIVED ERROR ! FROM THE
>                          IO SYSTEM (S/R 1557)
> 
>          CAUSE     STORE experienced an unexpected I/O system error.
> 
>          ACTION   The error shown here should be reported to your HP
>                         Support representative.
> 