Hi All,
I had rebooted an N-Class (N4000-100-330 on MPE/iX 7.0) server after replacing an SC10 18gb drive.....I am getting repeated Sys Aborts with the following when trying to restart the system:
SYSTEM ABORT 1348 FROM SUBSYSTEM 109
SYSTEM HALT 7, $0544
************* SYSTEM ALERT **************
SYSTEM NAME: uninitialized
DATE: 08/13/2012 TIME: 16:46:40
ALERT LEVEL: 12 = Software failure
REASON FOR ALERT
SOURCE: 0 = unknown, no source stated
SOURCE DETAIL: 0 = unknown, no source stated SOURCE ID: 0
PROBLEM DETAIL: 0 = no problem detail
LEDs: RUN ATTENTION FAULT REMOTE POWER
FLASH FLASH OFF ON ON
LED State: Running non-OS code. Non-critical error detected.
Check Chassis and Console Logs for error messages.
0xA0E010C00000B007 00000000 00000503 - type 20 = major change in system state
0x58E018C00000B007 00007007 0D102E28 - type 11 = Timestamp 08/13/2012 16:46:40
A: ack read of this entry - X: Disable all future alert messages
Anything else skip redisplay the log entry
->Choice:
I have 'a' the message, but continue to get the aborts when trying to restart the system.
Any Ideas ????
TIA, Dan
Dan Barnes ..:.. LCI-Lawinger Consulting
106 Central Avenue, Suite A ..:.. Osseo, MN, 55369-1243
Tel: 763-425-1639 ..:.. Fax: 763-425-5483 ..:.. Cell: 612-240-2136 ..:.. Pager: 952-394-0132
[log in to unmask] ..:.. [log in to unmask]
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|
|
|