Tracy,

When you boot up, with 

START NORECOVERY 

The system copies what ever group being used, (the default being CONFIG), to BOOTUP.   (remember there is a GROUP = option on the START command)

Then the system boots from BOOTUP.   This is the 'active' configuration.

A START RECOVERY,  boots from BOOTUP.

If you want to make changes to CONFIG

SYSGEN CONFIG

I am not sure you can do the same IOCONFIG.

Also, It is not possible to modify BOOTUP, since it is the active config.

-Craig



--- On Thu, 7/21/11, Johnson, Tracy <[log in to unmask]> wrote:

> From: Johnson, Tracy <[log in to unmask]>
> Subject: Basegroup = BOOTUP?
> To: [log in to unmask]
> Date: Thursday, July 21, 2011, 7:37 AM
> When going into IOCONFIG on one of my
> machines, I get the message below.
> I don't mind rebooting, but I wonder how it got this
> way?  Isn't the
> basegroup supposed to be CONFIG like on my other
> machines?  I'm thinking
> it may have occurred because the keyword NORECOVERY was
> skipped after
> START.
>  
>  
> /SYS/PUB:>ioconfig
> IOCONFIG A.00.00 (catalog A.00.00) (c) 1994 Hewlett-Packard
> Co. All
> Rights Reserved. THU, JUL 21, 2011,  1:46 PM 
>                
>   
>            
> ****************************WARNING*****************************
> 
>         The basegroup = BOOTUP,  a
> protected group.Any           
> 
>         configuration changes made can
> not be saved to this group
> 
>         and will be effective only
> until the next "boot" of the
> 
>         system. If any changes are to
> be permanent, use SYSGEN to
> 
>         switch basegroup, make the
> configuration changes permanent
> 
>         and then reboot with the
> "norecovery" option and specify
> 
>         the "new" basegroup.
> 
> ********************************************************************
>  
> 
> Tracy Johnson 
> Business Analyst 
> Measurement Specialties, Inc. 
> 1000 Lucas Way 
> Hampton, VA 23666 
> Office 1-757-766-4318 
> [log in to unmask]
> 
> www.meas-spec.com 
> 
>  
> 
> * To join/leave the list, search archives, change list
> settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
>

* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *

ATOM RSS1 RSS2