Hello all.
I am creating a portable subfile using Windows Powerhouse and transfering the file to the HP3000.
When I transfer the data and disctionary porrtion of the subfile in Reflections, I am using the following setting is WRQ.
For the data I am doing a Binary Transfer with a record size of 434.
For the dictionary I am doing a ASCII with a record size of 80.
My results are this:
FILENAME CODE ------------LOGICAL RECORD----------- ----SPACE----
SIZE TYP EOF LIMIT R/B SECTORS #X MX
QBTOHP 80B FA 95 204800 1 32 1 8
QBTOHPQ 217W VB 1350 1350 1 2320 5 1
and I can access and read the file fine.
But if I use dos to FTP the file to the HP3000 using the following ftp commands...
put qbtohp.ps qbtohpq;rec=-434,,v,binary
put qbtohp.psd qbtohp;rec=-80,,f,ascii
I get a warning message
ftp>
ftp> put qbtohp.ps qbtohpq;rec=-434,,v,binary
200 PORT command ok.
150 File: qbtohpq;rec=-434,,v,binary opened; data connection will be opened
226 Transfer complete. Some records were truncated during transfer.
ftp: 585900 bytes sent in 0.55Seconds 1071.12Kbytes/sec.
ftp> put qbtohp.psd qbtohp;rec=-80,,f,ascii
200 PORT command ok.
150 File: qbtohp;rec=-80,,f,ascii opened; data connection will be opened
226 Transfer complete.
ftp: 2411 bytes sent in 0.00Seconds 2411000.00Kbytes/sec.
ftp>
ftp> quit
221 Server is closing command connection
and my listf looks like the following....
FILENAME CODE ------------LOGICAL RECORD----------- ----SPACE----
SIZE TYP EOF LIMIT R/B SECTORS #X MX
QBTOHP 80B FA 95 204800 1 32 1 8
QBTOHPQ 217W VB 1 204800 1 16 1 8
When I access the subfile in quiz on the HP3000, I can only read 1 record.
Any idea's out here?
Thanks
Dave Vogt
Miller Compressing Company
Milwaukee, WI
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|