Yes.....
HP1659:ping.net.sys
-------- PING/XL (ICMP Echo Requestor) : Version B07000A2 --------
*******************************************************
| Information on Input Parameters: |
| |
| (CONTROL-Y at any point to exit to main level) |
| |
| IP address - In decimal form; (e.g) 15.13.131.55; |
| RETURN to quit program. |
| |
| # packets - Between 1 and 65534; RETURN for the |
| default of infinite packets, and |
| CONTROL-Y to stop sending. |
| |
| data bytes - Between 0 and 2048; should be 4 or |
| per packet more to get round trip times; RETURN |
| for the default of 64 bytes. |
*******************************************************
IP address [RETURN to quit program.] ? 127.0.0.1
------------------------------------
Remote IP address in hex : $7F000001
------------------------------------
# of packets [1 to 65534] ? 5
# of bytes of data [0 to 2048] ? 1024
---- PING $7F000001 : 1024 byte packet(s), 5 packet(s) ----
1024 byte(s) from $7F000001 : icmp_seq = 1, time = 32 ms
1024 byte(s) from $7F000001 : icmp_seq = 2, time = 0 ms
1024 byte(s) from $7F000001 : icmp_seq = 3, time = 1 ms
1024 byte(s) from $7F000001 : icmp_seq = 4, time = 1 ms
1024 byte(s) from $7F000001 : icmp_seq = 5, time = 1 ms
---- $7F000001 PING Statistics ----
5 packet(s) transmitted, 5 packet(s) received, 0 % packet loss
round trip (ms) min/avg/max = 0 / 7 / 32
-------- PING/XL (ICMP Echo Requestor) : Version B07000A2 --------
*******************************************************
| Information on Input Parameters: |
| |
| (CONTROL-Y at any point to exit to main level) |
| |
| IP address - In decimal form; (e.g) 15.13.131.55; |
| RETURN to quit program. |
| |
| # packets - Between 1 and 65534; RETURN for the |
| default of infinite packets, and |
| CONTROL-Y to stop sending. |
| |
| data bytes - Between 0 and 2048; should be 4 or |
| per packet more to get round trip times; RETURN |
| for the default of 64 bytes. |
*******************************************************
IP address [RETURN to quit program.] ?
HP1659:netcontrol ;net=loop;status
NETWORK STATUS : MON, DEC 20, 2010, 9:47 AM
PROTOCOL STARTED : SUN, DEC 19, 2010, 5:43 AM
PROTOCOL NAME : IP
PROTOCOL ID : $00000500
PROTOCOL FLAGS : $00000000
TRACE MASK : $00000000
PCB ADDR INFO : ENTRY $467D3448
TRACE INFO : ID : $00000000
PORT ID : $FFFFED99
NETWORK NAME : LOOP
NETWORK IP ADDRESS : $7F000001 127.0.0.1
NETWORK SUBNET MASK : $FF000000 255.0.0.0
HP1659:
Dan Barnes
LCI-Lawinger Consulting
106 Central Avenue, Suite A
Osseo, MN, 55369-1243
Tel: 763-425-1639 :: Fax: 763-425-5483
Cell: 612-240-2136 :: Pager: 952-394-0132
[log in to unmask]
[log in to unmask]
-----Original Message-----
From: Mark Ranft [mailto:[log in to unmask]]
Sent: Monday, December 20, 2010 9:45 AM
To: Dan Barnes; [log in to unmask]
Subject: RE: [HP3000-L] STM System Manager Problem
The first thing I would check is whether loopback was working on the system.
Mark Ranft
Pro 3K
-----Original Message-----
From: HP-3000 Systems Discussion [mailto:[log in to unmask]] On Behalf
Of Dan Barnes
Sent: Monday, December 20, 2010 9:31 AM
To: [log in to unmask]
Subject: [HP3000-L] STM System Manager Problem
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|