Here is DSTAT ALL, and I NEVER touched it or VOLUTIL...
:dstat all
LDEV-TYPE STATUS VOLUME VOLUME SET - GEN
---------- ------- ----------------------------------
1-ST318275LC MASTER MEMBER1 MPEXL_SYSTEM_VOLUME_SET-0
2-ST39175LC MEMBER MEMBER2 MPEXL_SYSTEM_VOLUME_SET-0
And
Discfree c
| Configured | In Use | Available |
-----------+-------------------+-------------------+-------------------+
LDEV : 1 -- (MPEXL_SYSTEM_VOLUME_SET:MEMBER1)
Device | 71132944 | 4491168 ( 6%) | 66641776 ( 94%) |
Permanent | 53349696 ( 75%) | 3946544 ( 6%) | 49403152 ( 69%) |
Transient | 53349696 ( 75%) | 544624 ( 1%) | 52805072 ( 74%) |
LDEV : 2 -- (MPEXL_SYSTEM_VOLUME_SET:MEMBER2)
Device | 35547040 | 9642304 ( 27%) | 25904736 ( 73%) |
Permanent | 35547040 (100%) | 9642304 ( 27%) | 25904736 ( 73%) |
Transient | 35547040 (100%) | 0 ( 0%) | 25904736 ( 73%) |
The clock SA problem is OK now.
Regards,
John Pitman
-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: Tuesday, 23 November 2010 3:17 AM
To: [log in to unmask]; John Pitman
Cc: [log in to unmask]
Subject: Re: [HP3000-L] 959 ans sa 1328
Hi JOhn,
Is/was the clock properly set?
Subsys 110 is CLOCKS... SA 3128 is in the CLOCKS module...
Do a DSTAT ALL to verify if ldev 2 is in use in the MPEXL_SYSTEM_VOLUME_SET.
Usually after an install, only ldev 1 is active in the system volumeset and you have to use volutil (NEWVOL MPEXL_SYSTEM_VOLUME_SET:MEMBER2 2 100 100) to initialize all the other members of the volume set...
Thanks,
Gary Robillard
---- John Pitman <[log in to unmask]> wrote:
> I rebooted it with noecovery nosysstart , and it got up OK....
> ?? where to now?
>
> Thanks
> jp
>
>
> ________________________________
> CAUTION: This message may contain privileged and confidential information intended only for the use of the addressee named above. If you are not the intended recipient of this message you are hereby notified that any use, dissemination, distribution or reproduction of this message is prohibited. If you have received this message in error please notify RYCO Hydraulics Pty. Ltd. immediately. Any views expressed in this message are those of the individual sender and may not necessarily reflect the views of RYCO Hydraulics Pty. Ltd.
>
> * To join/leave the list, search archives, change list settings, *
> * etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
CAUTION: This message may contain privileged and confidential information intended only for the use of the addressee named above. If you are not the intended recipient of this message you are hereby notified that any use, dissemination, distribution or reproduction of this message is prohibited. If you have received this message in error please notify RYCO Hydraulics Pty. Ltd. immediately. Any views expressed in this message are those of the individual sender and may not necessarily reflect the views of RYCO Hydraulics Pty. Ltd.
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *
|