Has anyone had this problem with UPSUTIL - shows the state as "Down/Broken"?
UPS DEVICES STATUS:
UPS# Ldev# Alloc Init State Power Hardware Status
~~~~ ~~~~~~ ~~~~~ ~~~~ ~~~~~~~~~~~~ ~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
1 22 Yes No Down/Broken ??? ???
I have an A1353A UPS+A1357A battery pack connected to an e3000 A500-200-200
via a HP UPS serial cable (p/n 5061-2575).
I have checked the configuration (SYSGEN & NMMGR). I have also tried
another serial cable and even swapped out the A1353A and I am getting the
same result.
SYSGEN:
LDEV: 22 DEVNAME: OUTDEV: 22 MODE: JAID
ID: HPUPS RSIZE: 40 DEVTYPE: TERM
PATH: 0/0/4/1.2 MPETYPE: 16 MPESUBTYPE: 0
CLASS: HPUPSDEV
NMMGR - UPS is configured for ldev 22, 1200 baud and no parity (Data: Y)
Thanks!
Thor
_____
Thor Engstrom
IT Manager
Reuland Electric
17969 East Railroad Street
City of Industry, CA 91748-1192
626-854-5101 (direct)
[log in to unmask]
* To join/leave the list, search archives, change list settings, *
* etc., please visit http://raven.utc.edu/archives/hp3000-l.html *