Attach your IMAGE DB to Allbase using IMAGESQL and use the SPLIT command 
to break apart the X fields so they are mapped correctly

Pint your ODBC driver at the Allbase bridged table.

http://docs.hp.com/en/36385-90012/ch04s19.html

Ken Vickers
LINKWAY

On 19/02/2010 18:42, Greg Terterian wrote:
> no it does not Rene.  He is using ODBC, but on Image site the field is X100 and it is consist of X20 field, X10 field, Comp field, X2 field, Comp field, X12 field and Xbuffer for the rest
> So through ODBC he is getting X100 into string in VB and in VB he needs to do the breaking of the fields...
>
>
>
>